📌 Key Takeaways
- Topic: Tosoh Silica: Product Range, Applications and Key Grades
- Keywords: silica gel desiccant
- Published: 2026-11-20 07:06:28
- Field: Silica (SiO₂) raw materials · Inorganic non-metallic materials · Chemicals
How to Modify Nano Silica: Surface Modification Methods and Silane Selection
- Kaolin vs Silica: Filler Properties, Uses and Selection Guide
- Ho et al. employed the Multiple-Path Particle Dosimetry (MPPD) model for aerosolization and determination of lung deposition of silver nanoparticles, which method may be broadened to other materials like mesoporous silica nanoparticles [ 87 ]. It suggests particle size (mean 18 nm), density, and generation approach as principal elements that determine aerosolization efficiency and inhaled dose. Simulations of airflow, diffusion, sedimentation, and impact through airway generations yield comparable alveolar deposition fractions for particles less than 100 nm in humans and rats. With the addition of species-specific parameters, such as respiratory rate, lung surface region, tidal volume, and finished with possible lobar- and airway-level analysis, the MPPD model makes realistic regional retention predictions. Given that mesoporous silica nanoparticles are of similar size and physicochemical properties, the same methodology can estimate their aerosolization and lung deposition. In summary, the MPPD model is a handy tool in the assessment of inhalation danger and in guiding the formulation of safer nanomaterials [ 87 ]. In another study, Ali et al. applied the MPPD model to simulate aerosolization and lung deposition of mesoporous silica nanoparticles [ 88 ]. Pre-characterized MSNs with pre-specified aerodynamic diameters were initially assessed through scanning mobility particle sizing to yield accurate size-distribution inputs. Asymmetric mouse airway geometry and physiological parameters such as respiratory rate, lung volume, and airflow were used in simulations that were approximated to provide a total lung deposition of about 45%, of which 37% was in the head, 27% in the tracheobronchial, and 36% in the pulmonary (alveolar) region. These predictions are in reasonable agreement with earlier in vivo findings, validating the model. MPPD analysis also indicated that smaller MSNs exhibit more alveolar deposition, with the larger particles being better in the upper airways. Through linking aerosolization efficiency (via size distribution and concentration) and regional deposition, this modeling approach orients optimization of nanoparticle size and generation techniques toward maximizing targeted lung delivery [ 88 ]. To achieve easier production of aerosols, the surface of nanoparticles is often provided with a polymer coating, thereby stabilizing their distribution and increasing dispersibility [ 56 ]. By lowering the particle size, deeper lung areas can be reached [ 25 ]. Particles smaller than 1 µm are capable of accumulating in the alveoli, but the ideal size range to achieve maximum efficiency is in the 200-500 nm range [ 25 ]. Nevertheless, another review cited that particle size in the range of 50-200 nm is ideal for maximizing drug localization by inhalation [ 89 ]. It has also been recommended that the perfect diameter is approximately 500 nm for phagocytosis by alveolar macrophages [ 89 ]. Li et al. nebulized PEI-PEG-coated MSNs (50 nm particle size) by standard nebulizers without compromising their structure, while keeping particles in their individual form within the water droplets [ 90 ]. The aerosol supplies convenient delivery of MSNs to all areas of the respiratory tract - nasal, tracheobronchial, and pulmonary - and they persist for a week following inhalation, mostly within alveolar macrophages. It offers intracellular targeted delivery of lung diseases without passing through the gastrointestinal and first-pass metabolism. In spite of decreased deep lung deposition in mice under nasal breathing, exposure is comparable to that of humans with inhalation. Toxicity tests revealed no tissue damage or inflammation, further supporting MSN inhalation as a safe and effective method for vast treatment of pulmonary diseases, feasible for clinical translation [ 90 ]. A study investigated the effect of surface chemistry on drug loading capacity, release kinetics, and antibiotic activity in pulmonary infections on S. aureus bacterial cultures [ 18 ]. The model drugs were isoniazid, rifampicin, and vancomycin. Remarkable absorption ability was observed only with thiol (-SH) grafted carriers for all the tested drugs [ 18 ]. The in vitro drug release study showed sustained, but limited release: the cumulative release of rifampicin was 78.5% after 12 days, estimated by antibiogram [ 18 ]. Interestingly, the MIC values of the MSN-drug complex were higher for the free drug, probably due to the delayed and incomplete release from the pores [ 18 ]. Wang et al. developed a polydopamine-coated MSN formulation co-loaded with Ziyuglycoside I and Oseltamivir for the treatment of viral pneumonia. Interestingly, in vitro and in vivo studies have demonstrated that this carrier provided immediate release of Oseltamivir (allows quick virus killing) but prolonged release of Ziyuglycoside I (cuts down the inflammatory response for a longer period) [ 62 ].
- Silica Testing Methods: How to Test Purity, Particle Size, BET and Moisture
- 22. Tahir H., Shahzad Y., Waters L.J., Hussain T., Yousaf A.M., Mahmood T., Sheikh R. Impact of processing methods on the dissolution of artemether from two non-ordered mesoporous silicas. Eur. J. Pharm. Sci. 2018;112:139-145. doi: 10.1016/j.ejps.2017.11.016. [ DOI ] [ PubMed ] [ Google Scholar ]
- Silica for Sealants: Grades, Functions and Formulation Guide
- Utilizing DE as a Pesticide
- Silica for Battery Separator: Benefits for Lithium-Ion and Lead-Acid Batteries
Wood Coating Matting Agent: How to Achieve a Low-Gloss, Clear Finish
What is silica (SiO₂)?
colloidal silica
What is the difference between fumed silica and precipitated silica?
silica testing method
What drives silica raw material prices?
fused silica sand The carriers can have ordered and disordered pore structures [ 1, 2 ]. The ordered mesopores have a regular, homogeneous pore structure and a tunable internal frame, which permits the optimization of the API formulation, while the disordered ones have a random distribution of pore structure. Pores can be divided into two chief groups according to their geometry. There are open and closed pores, based on whether the pore is accessible to the medium or not. In the case of open pores, further differentiation is also possible. Blind pores are only accessible from one direction, while through pores are accessible from at least two directions [ 3 ]. The arrangement of the pores can also be defined and changed, hence the kinetics and dynamics of the release of the API can be influenced and regulated [ 1 ]. Laminar (tubular), radial, hexagonal, or cubic arrangements can also be created [ 1 ]. It is well known that the pore size significantly affects drug loading and drug release [ 1, 3 ]. Nonetheless, the literature is not crystal clear regarding correlation [ 14 ]. Some studies show proof that larger pores provide faster drug release [ 15, 16, 26 ], and larger pores have demonstrated a faster degradation rate in the lymph nodes [ 15 ], and reports limited release for smaller pores as they limit the diffusion process, which is called the steric hindrance influence [ 16, 26 ]. Nevertheless, in other publications, proof recommends that larger pores facilitate slower drug release, as the drug is loaded and trapped in deeper channels, requiring a longer access time for the release medium [ 14 ]. In general, the adsorption capacity can indeed be increased by increasing the specific surface area of the carrier and by decreasing the pore diameter [ 17 ].
/news/article.htmlDisclaimer: Prices and data are for reference only and do not constitute purchasing or investment advice. Please credit the source when republishing.